Telos NX12 User Manual Page 33

  • Download
  • Add to my manuals
  • Print
  • Page
    / 133
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 32
INSTALLATION | 23
PIN DESCRIPTION
5 Record Start 1
6 Ring Mute In 1
7 N/C
8 +5VDC (50mA max)
9 Record Stop 1
10 User Out (Dump) 2
11 Ringing Out 2
12 Priority Ringing Out 2
13 Ring Mute In 2
14 (reserved)
15 N/C
P
A
R
A
L
L
E
L
C
O
N
T
R
O
L
1
8
Note for the Curious
The DB- designation for D-Sub connectors is from Cinch Corp’s part numbering system. The
proper Cinch designation for a 15 pin D-Sub connector is a DA-15p (plug) or DA-15s (socket)
not DB-15! (Our thanks to Mike Schweizer, for contributing this tidbit.)
Input Characteristics
e NX12’s inputs are designed to be universal. ey accept either a voltage source up
to 24VDC, or a closure to ground, which may be provided by switches, relays, or logic
outputs. In the latter case either ‘totem-pole or open-collector will work. e inputs are
active low.
A built in 1k Ohm pull up resistor is provided.
Parallel logic input circuit:
3
0
v
m
a
x
+5V
Output Characteristics
Open collector to ground.
ese will require a pull-up resistor to drive TTL-style logic inputs. Most equipment has
the pull-up built into the input, but if there is no pull-up, youll have to add one, connect-
Page view 32