48 | Section 5
Input Setting Related to Input Level
Input Setting -10dBV 0dBu +4dBu +9dBu PPM -9dBfs PPM
Analog input level - 10 dBV nom 0 dBu nom +4 dBu nom +9 dBu PML n/a
Livewire/AES - 32 dBfs nom -24 dBfs nom -20 dBfs nom -15 dBfs -9 dBfs PML
e ballistic (time) characteristic of Nx12’s meters changes depending on the Input Level set-
ting so to match the expected console meter type. When -10, 0, or +4dBu is selected, the meter
has a VU-standard integration time. When +9dBu PPM or -9dBfs PPM are selected, the meter
has a PPM time characteristic.
e table above shows the level at the green/red transition on the NX12 meter. For VU, this is
the nominal 0 value; for PPM, this is the Permitted Maximum Level (PML) value.
e usual setting is +4dBu. e +9dBu PPM setting is intended for Euro analog installations.
e -9dBfs setting is intended for Euro digital installations.
If Livewire inputs are used, this should usually be set to +4dBu for the -20dBfs Livewire
standard nominal level. Europeans could choose the -9dBfs PPM setting if they are operating
their Livewire network according to this standard.
Nominal Output Level
is adjusts the level of analog, AES, and Livewire outputs.
Output Setting Related to Output Level
Output Gain Setting -10dBV 0dBu +4dBu +9dBu PPM -9dBfs PPM
Analog output level - 10 dBV nom 0 dBu nom +4 dBu nom +9 dBu PML n/a
Livewire/AES - 32 dBfs nom -24 dBfs nom -20 dBfs nom -15 dBfs -9 dBfs PML
Meter Mode
Selects the audio that will be indicated on the LED meters.
4 Studio Out
– Each studio output goes to a meter, from the top down
4 Studio In –
Each studio input has a meter, from the top down
POH in –
e two Program on Hold inputs go to the top meters
Phone 3&4 –
Send and receive to/from hybrids 3 & 4
Phone 1&2 –
Send and receive to/from hybrids 1 & 2
Studio 3&4
– Input from and output to studios 3 & 4
Studio 1&2 (default)
– Input from and output to studios 1 & 2 (the meter markings
correspond to this one)
Phone Send Adjustment
is setting adjusts the level of the hybrid into the telephone line, after the send limiter and is
calibrated with 0dB representing the usual send level into the line.
e default is 0dB, which should be OK for most telephone lines. If callers consistently com-
plain about low audio level and you have verified that this is a problem, you can increase the
Page view 57